Failure of the ON BAT Light on the ADIRS CDU
TASK 34-13-00-810-937-A
Failure of the ON BAT Light on the ADIRS CDU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-152-A ** ON A/C NOT FOR ALL
Subtask 34-13-00-810-187-A ** ON A/C NOT FOR ALL
Subtask 34-13-00-860-063-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:29 UTC
Failure of the ON BAT Light on the ADIRS CDU
1. Possible Causes
- bulb
- CDU-ADIRS [2FP]
- wiring
FAULT LT-ADIRS/ON BAT (28FP)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-14-00-710-001 | Operational Test of the Lights |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 34-10-00-860-005 | ADIRS Stop Procedure |
| ASM 341101 | |
| ASM 341102 | |
| AMM 34-12-12-000-001 | Removal of the ADIRS CDU |
| AMM 34-12-12-400-001 | Installation of the ADIRS CDU |
Subtask 34-13-00-710-152-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the ADIRS start procedure AMM 34-10-00-860-002.
Subtask 34-13-00-710-152-B ** ON A/C NOT FOR ALL (1) Do the ADIRS start procedure AMM 34-10-00-860-002.
NOTE: The ADIRS start procedure is correct but, during the procedure, at Para. 3.B., make sure that:
- on the ADIRS CDU, the ON BAT light does not come on.
A. Test
(1) Do the ADIRS start procedure AMM 34-10-00-860-002.
4. Fault Isolation(1) Do the ADIRS start procedure AMM 34-10-00-860-002.
NOTE: The ADIRS start procedure is correct but, during the procedure, at Para. 3.B., make sure that:
- On the ADIRS MSU, the ON BAT light does not come on.
Subtask 34-13-00-810-187-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
Subtask 34-13-00-710-153-A ** ON A/C NOT FOR ALL - do the operational test of the annunciator light test system AMM 33-14-00-710-001.
- replace the bulb .
- replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001.
- replace the CDU-ADIRS [2FP] AMM 34-12-12-000-001 and AMM 34-12-12-400-001.
- do a check and repair the wiring from pins A/16, B/16, C/16 of the ADIRS CDU (2FP) to the first terminal block ASM 341101.
B. Make sure that the system operates correctly:
(1) Do the action given in Para. 3. and make sure that:
Subtask 34-13-00-810-187-B ** ON A/C NOT FOR ALL (1) Do the action given in Para. 3. and make sure that:
- on the ADIRS CDU, the ON BAT light comes on.
C. If the test confirms the fault:
Subtask 34-13-00-710-153-B ** ON A/C NOT FOR ALL - Do the operational test of the annunciator light test system AMM 33-14-00-710-001.
- Replace the bulb .
- Replace the
FAULT LT-ADIRS/ON BAT (28FP) .
- Do a check and repair the wiring of the ADIRS/ON BAT fault light (28FP):
. From pin 2 to DIODE (2403VD) pin 1
. From pin 2 to DIODE (2403VD) pin 2
. From pin 2 to DIODE (2403VD) pin 4
. From pin 2 to DIODE (2403VD) pin 5
. From pin 4 to to the first terminal block ASM 341102.
D. Make sure that the system operates correctly:
(1) Do the procedure given in Para. 3. and make sure that:
5. Close-up(1) Do the procedure given in Para. 3. and make sure that:
- On the ADIRS MSU, the ON BAT light comes on.
Subtask 34-13-00-860-063-A