Failure of the ADIRU3 Detected by the Cabin Pressure Controller
TASK 34-13-00-810-936-A
Failure of the ADIRU3 Detected by the Cabin Pressure Controller
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-150-A 4. Fault Isolation
Subtask 34-13-00-810-186-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:29 UTC
Failure of the ADIRU3 Detected by the Cabin Pressure Controller
1. Possible Causes
- ADIRU-3 [1FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-31-00-710-002 | Operational Test of the Pressure Control and Monitoring |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-710-150-A 4. Fault Isolation
Subtask 34-13-00-810-186-A
A. If the test gives the maintenance message ADIRS3 OUT OF RANGE:
Subtask 34-13-00-710-151-A - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.