Loss of the ADIRU3 Input Signal from the SFCC
TASK 34-13-00-810-933-A
Loss of the ADIRU3 Input Signal from the SFCC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-249-B 4. Fault Isolation
Subtask 34-13-00-810-183-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:29 UTC
Loss of the ADIRU3 Input Signal from the SFCC
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-932-A | Failure of the Discrete Links |
| AMM 27-50-00-866-008 | Extension of the Flaps on the Ground |
| AMM 27-50-00-866-009 | Retraction of the Flaps on the Ground |
| ASM 275110 | |
| AMM 27-51-34-000-001 | Removal of the SFCC |
| AMM 27-51-34-400-001 | Installation of the SFCC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| AMM 34-13-00-740-005 | Read the CFDIU for the ADR INPUT STATUS |
| ASM 341302 |
Subtask 34-13-00-740-249-B 4. Fault Isolation
Subtask 34-13-00-810-183-B
A. If the test gives the SFCC1(21CV)/SFCC2(22CV)/ ADIRU3 (1FP3) maintenance message:
(1) Put the aircraft in each of the configurations given below AMM 34-13-00-740-005.
(a) Retract the flaps to the 0 position AMM 27-50-00-866-009.
(a) Replace the SLAT/FLAP CONTR.COMP. [21CV] AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(b) If the fault continues:
Do a check and repair the wiring between:
(a) Replace the SLAT/FLAP CONTR.COMP. [22CV] AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(b) If the fault continues:
Do a check and repair the wiring between:
Subtask 34-13-00-740-250-A (1) Put the aircraft in each of the configurations given below AMM 34-13-00-740-005.
(a) Retract the flaps to the 0 position AMM 27-50-00-866-009.
- Do a check of the input discrete statuses with the ADR CURRENT STATUS page of ADIRU3:
AOA Correction Discrete 1A (Pin AA/2J) = OPN
AOA Correction Discrete 1B (Pin AA/12F) = OPN
AOA Correction Discrete 2A (Pin AA/11F) = OPN
AOA Correction Discrete 2B (Pin AA/14F) = OPN
SSEC Select 1 Discrete (Pin AA/2H) = OPN
SSEC Select 2 Discrete (Pin AA/2K) = OPN.
- Do a check of the input discrete statuses with the ADR CURRENT STATUS page of ADIRU3:
AOA Correction Discrete 1A (Pin AA/2J) = GND
AOA Correction Discrete 1B (Pin AA/12F) = OPN
AOA Correction Discrete 2A (Pin AA/11F) = GND
AOA Correction Discrete 2B (Pin AA/14F) = OPN.
- Do a check of the input discrete statuses with the ADR CURRENT STATUS page of ADIRU3:
AOA Correction Discrete 1A (Pin AA/2J) = GND
AOA Correction Discrete 1B (Pin AA/12F) = GND
AOA Correction Discrete 2A (Pin AA/11F) = GND
AOA Correction Discrete 2B (Pin AA/14F) = GND
SSEC Select 1 Discrete (Pin AA/2H) = GND
SSEC Select 2 Discrete (Pin AA/2K) = GND.
(a) Replace the SLAT/FLAP CONTR.COMP. [21CV] AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(b) If the fault continues:
- Replace ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
Do a check and repair the wiring between:
- Pin AA/2J of ADIRU3 (1FP3) and the first terminal block
- Pin AA/12F of ADIRU3 (1FP3) and the first terminal block
- Pin AA/2H of ADIRU3 (1FP3) and the first terminal block ASM 341302.
- Do the troubleshooting procedure (Ref. TSM TASK 31-32-00-810-932) related to the discrete output signal (FAP£5, pin AB/8K) of SFCC1 (21CV) ASM 275110.
(a) Replace the SLAT/FLAP CONTR.COMP. [22CV] AMM 27-51-34-000-001 and AMM 27-51-34-400-001.
(b) If the fault continues:
- Replace ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
Do a check and repair the wiring between:
- Pin AA/11F of ADIRU3 (1FP3) and pin AB/8D of SFCC2 (22CV)
- Pin AA/14F of ADIRU3 (1FP3) and pin AB/10H of SFCC2 (22CV)
- Pin AA/2K of ADIRU3 (1FP3) and the first terminal block ASM 341302.
- Do the troubleshooting procedure (Ref. TSM TASK 31-32-00-810-932) related to the discrete output signal (FAP£3, pin AB/8F) of SFCC2 (22CV) ASM 275110.
B. Do the test given in Para. 3.