W DOC AIRBUS | TSM A320F

Loss of the ADIRU1 Input B Signal from the SFCC


TASK 34-13-00-810-926-A
Loss of the ADIRU1 Input B Signal from the SFCC


1. Possible Causes
  • SLAT/FLAP CONTR.COMP. [21CV]
  • SLAT/FLAP CONTR.COMP. [22CV]
  • wiring
  • ADIRU-1 [1FP1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-51-34-000-001
Removal of the SFCC
AMM 27-51-34-400-001
Installation of the SFCC
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341302
3. Fault Confirmation
Subtask 34-13-00-740-235-C
A. Test
   (1) Do the interface test of the ADR (system 1) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-176-B
A. If the test gives the SFCC1/2 (21CV/22CV)/ ADIRU1 (1FP1) AOA INPUT B maintenance message:
   (1) If the fault continues:
   (2) If the fault continues:
Do a check and repair the wiring between:
  • Pin AA/12F of ADIRU1 (1FP1) and the first terminal block
  • Pin AA/14F of ADIRU1 (1FP1) and pin AB/10H of SFCC2 (22CV)
  • Pin AA/2K of ADIRU1 (1FP1) and the first terminal block ASM 341302.
   (3) If the fault continues:
Subtask 34-13-00-740-236-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:28 UTC