W DOC AIRBUS | TSM A320F

Loss of the ADR3 Bus 2 Output Identified by the EIS2


TASK 34-13-00-810-914-A
Loss of the ADR3 Bus 2 Output Identified by the EIS2


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring of the ADR OUTPUT BUS 2 bus from the ADIRU3 (1FP3) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341301
3. Fault Confirmation
Subtask 34-13-00-740-225-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the EIS input test (system 2) AMM 31-60-00-740-002.
Subtask 34-13-00-740-225-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the Ground Scanning Test of the DMC (system 2) AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 34-13-00-810-163-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : NO ADC3 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU3 (1FP3) to the first terminal block ASM 341301.
Subtask 34-13-00-810-163-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU3(1FP3)BUSX ADR/DMC2(1WT2)
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU3 (1FP3) to the first terminal block ASM 341301.
Subtask 34-13-00-740-226-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:28 UTC