W DOC AIRBUS | TSM A320F

Loss of the TAT Sensor 1 Input on the ADR1


TASK 34-13-00-810-909-A
Loss of the TAT Sensor 1 Input on the ADR1


1. Possible Causes
  • SENSOR-TAT, 1 [11FP1]
  • ADIRU-1 [1FP1]
  • wiring from the TAT sensor 1 to the ADIRU1
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 30-31-00-810-803-A
Loss of the GND/FLT Information (PHC 1)
AMM 30-31-00-710-001
Operational Test of the Probe Ice Protection
ASM 341102
AMM 34-11-18-000-001
Removal of the TAT Sensor
AMM 34-11-18-400-001
Installation of the TAT Sensor
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-00-740-217-A
A. Test
Do the Interface test of the ADR (system 1) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-158-B
A. If the test gives the maintenance message TAT SENSOR (11FP1)/ ADIRU1 (1FP1):
   (1) If you cannot start the test:
   (2) If the test is OK:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check and repair the wiring from the TAT sensor 1 to the ADIRU1 ASM 341102.
Subtask 34-13-00-740-218-A
B. Do the test given in Para. 3.