Loss of the AOA 3 Input to the ADR 3
TASK 34-13-00-810-908-A
Loss of the AOA 3 Input to the ADR 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-215-A 4. Fault Isolation
Subtask 34-13-00-810-157-B
[Rev.8 from Aug 2018]
2026.04.04 04:40:01 UTC
Loss of the AOA 3 Input to the ADR 3
1. Possible Causes
- SENSOR-ANGLE OF ATTACK, 3 [3FP3]
- ADIRU-3 [1FP3]
wiring from the angle of attack sensor 3 (3FP3) to the AOA INPUTS 1 and 2 of the ADIRU 3 (1FP3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 341102 | |
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-00-740-215-A 4. Fault Isolation
Subtask 34-13-00-810-157-B
A. If the test gives the maintenance message AOA SENSOR3 (3FP3)/ ADIRU3 (1FP3):
Subtask 34-13-00-810-254-A ** ON A/C NOT FOR ALL - replace the SENSOR-ANGLE OF ATTACK, 3 [3FP3] AMM 34-11-19-000-001 and AMM 34-11-19-400-001
- replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring from the angle of attack sensor 3 (3FP3) to the AOA INPUTS 1 and 2 of the ADIRU 3 (1FP3) ASM 341102.
B. If the test is OK, reset the ADIRU (NAV-OFF-NAV) to clear the ECAM message. No other maintenance action is necessary.
Subtask 34-13-00-740-216-A C. Do the test given in Para. 3.