Internal Failure of the ADR 2 Identified by the EFCS 2
TASK 34-13-00-810-895-A
Internal Failure of the ADR 2 Identified by the EFCS 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-163-A 4. Fault Isolation
Subtask 34-13-00-810-144-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:27 UTC
Internal Failure of the ADR 2 Identified by the EFCS 2
1. Possible Causes
- ADIRU-2 [1FP2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-13-81-810-824-A | Runaway or Drift of One ADR2 Parameter Identified by the ELACs and the SECs |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-740-163-A 4. Fault Isolation
Subtask 34-13-00-810-144-A
A. If the test gives the maintenance message ADR2:
Subtask 34-13-00-740-164-A - read the Post Flight Report (PFR) for the maintenance messages related to the link between SEC and ADR.
- do this trouble shooting procedure: (Ref. TSM TASK 34-13-81-810-824).
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.