W DOC AIRBUS | TSM A320F

Loss of the ADR 3 BUS 3 Output Identified by the EIS 1


TASK 34-13-00-810-894-A
Loss of the ADR 3 BUS 3 Output Identified by the EIS 1


1. Possible Causes
  • ADIRU-3 [1FP3]
  • wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341301
3. Fault Confirmation
Subtask 34-13-00-740-162-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS input test (system 1) AMM 31-60-00-740-002.
Subtask 34-13-00-740-162-B ** ON A/C NOT FOR ALL
A. Test
Do the Ground Scanning Test of the DMC (system 1) AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 34-13-00-810-143-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 1 : NO ADC 3 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block ASM 341301.
Subtask 34-13-00-810-143-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU3(1FP3)BUSX ADR/DMC1(1WT1)
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 3 (1FP3) to the first terminal block ASM 341301.
Subtask 34-13-00-740-182-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:27 UTC