Loss of the ADR 2 BUS 3 Output Identified by the EIS 3
TASK 34-13-00-810-881-A
Loss of the ADR 2 BUS 3 Output Identified by the EIS 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-175-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-175-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-130-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:26 UTC
Loss of the ADR 2 BUS 3 Output Identified by the EIS 3
1. Possible Causes
- ADIRU-2 [1FP2]
wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 2 (1FP2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341301 |
Subtask 34-13-00-740-175-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-175-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-130-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO ADC 2 DATA:
Subtask 34-13-00-810-130-B ** ON A/C NOT FOR ALL - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 2 (1FP2) to the first terminal block ASM 341301.
A. If the test gives the maintenance message ADIRU2(1FP2)BUS2 ADR/DMC3(1WT3)
Subtask 34-13-00-740-176-A - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 2 (1FP2) to the first terminal block ASM 341301.
B. Do the test given in Para. 3.