Loss of the ADR 2 BUS 2 Output Identified by the EFCS 1
TASK 34-13-00-810-872-A
Loss of the ADR 2 BUS 2 Output Identified by the EFCS 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-169-A 4. Fault Isolation
Subtask 34-13-00-810-121-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:26 UTC
Loss of the ADR 2 BUS 2 Output Identified by the EFCS 1
1. Possible Causes
- ADIRU-2 [1FP2]
wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341301 |
Subtask 34-13-00-740-169-A 4. Fault Isolation
Subtask 34-13-00-810-121-A
A. If the test gives the maintenance message ADR2 BUS 2:
Subtask 34-13-00-740-170-A - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block ASM 341301.
B. Do the test given in Para. 3.