Internal Failure of the ADR 2 Identified by the AFS
TASK 34-13-00-810-861-A
Internal Failure of the ADR 2 Identified by the AFS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-092-A 4. Fault Isolation
Subtask 34-13-00-810-110-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:25 UTC
Internal Failure of the ADR 2 Identified by the AFS
1. Possible Causes
- ADIRU-2 [1FP2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-710-092-A 4. Fault Isolation
Subtask 34-13-00-810-110-A
A. If the test gives the maintenance message AFS : ADIRU 2:
Subtask 34-13-00-710-093-A - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.