Internal Failure of the ADR 2 Identified by the CFDS


TASK 34-13-00-810-858-A
Internal Failure of the ADR 2 Identified by the CFDS


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 34-13-00-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
Subtask 34-13-00-740-121-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 34-13-00-810-107-A
A. If the test gives the maintenance message NO ADR 2 DATA:
Subtask 34-13-00-740-122-A
B. Do the test given in Para. 3.B.