Internal Failure of the ADR 2 Identified by the ECAM 1
TASK 34-13-00-810-855-A
Internal Failure of the ADR 2 Identified by the ECAM 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-086-A 4. Fault Isolation
Subtask 34-13-00-810-104-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:25 UTC
Internal Failure of the ADR 2 Identified by the ECAM 1
1. Possible Causes
- ADIRU-2 [1FP2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-710-086-A 4. Fault Isolation
Subtask 34-13-00-810-104-A
A. If the test gives the maintenance message FWC 1 : NO DATA FROM ADC 2:
Subtask 34-13-00-710-087-A - replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.