1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 34-13-00-710-084-A
A. Test
Do the operational test of the central warning systems (system 2) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 34-13-00-810-102-A
A. If the test gives the maintenance message FWC 2 : NO DATA FROM ADC 2:
Subtask 34-13-00-710-085-A
B. Do the test given in Para. 3.