W DOC AIRBUS | TSM A320F

Internal Failure of the ADR 2


TASK 34-13-00-810-851-A
Internal Failure of the ADR 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-12-34-610-801
Uploading of Software to the ADIRUs
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-13-00-740-113-A
A. Test
Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-100-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU2 (1FP2):
Subtask 34-13-00-810-100-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU2 (1FP2):
   (1) If the fault continues: