W DOC AIRBUS | TSM A320F

Loss of the ADR 1 BUS 3 Output Identified by the EFCS 2


TASK 34-13-00-810-850-A
Loss of the ADR 1 BUS 3 Output Identified by the EFCS 2


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block
  • wiring between the terminal blocks 1510VT and 1851VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
AWM 341121
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341301
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-13-00-740-111-A
A. Test
Do the BITE test of the EFCS (ground scanning) (system 2) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 34-13-00-810-099-A
A. If the test gives the maintenance message ADR1 BUS 3:
   (1) If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU3 (1FP3):
     (a) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block ASM 341301.
   (2) If the test does not give the maintenance message ADIRU1 (1FP1)/ADIRU3 (1FP3):
  • do a check and repair the wiring between the terminal blocks 1510VT and 1851VT : between pins 1X, 1Y and 2E, 1E AWM 341121.
Subtask 34-13-00-740-112-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:24 UTC