W DOC AIRBUS | TSM A320F

Loss of the ADR 1 BUS 4 Output Identified by the GPWC


TASK 34-13-00-810-839-A
Loss of the ADR 1 BUS 4 Output Identified by the GPWC


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the ADR OUTPUT BUS 4 bus from the ADIRU 1 (1FP1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341301
AMM 34-48-00-740-002
BITE Test of the GPWS
3. Fault Confirmation
Subtask 34-13-00-740-093-B
A. Test
Do the BITE test of the Enhanced GPWS AMM 34-48-00-740-002.
4. Fault Isolation
Subtask 34-13-00-810-088-A
A. If the test gives the maintenance message ADIRU1(1FP1)/GPWC(1WZ):
   (1) If the fault continues:
  • do a check and repair the wiring of the ADR OUTPUT BUS 4 bus from the ADIRU 1 (1FP1) to the first terminal block, ASM 341301.
Subtask 34-13-00-740-094-A
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:32:24 UTC