Internal Failure of the ADR 3 Identified by the ECAM 1
TASK 34-13-00-810-834-A
Internal Failure of the ADR 3 Identified by the ECAM 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-080-A 4. Fault Isolation
Subtask 34-13-00-810-083-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:23 UTC
Internal Failure of the ADR 3 Identified by the ECAM 1
1. Possible Causes
- ADIRU-3 [1FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-710-080-A 4. Fault Isolation
Subtask 34-13-00-810-083-A
A. If the test gives the maintenance message FWC 1 : NO DATA FROM ADC 3:
Subtask 34-13-00-710-081-A - replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.