Loss of the ADR 1 BUS 3 Output Identified by the EIS3
TASK 34-13-00-810-831-A
Loss of the ADR 1 BUS 3 Output Identified by the EIS3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-082-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-082-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-080-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:22 UTC
Loss of the ADR 1 BUS 3 Output Identified by the EIS3
1. Possible Causes
- ADIRU-1 [1FP1]
wiring of the ADR OUTPUT BUS 3 from the ADIRU 1 (1FP1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341301 |
Subtask 34-13-00-740-082-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-082-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-080-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC3 : NO ADC1 DATA:
Subtask 34-13-00-810-080-B ** ON A/C NOT FOR ALL - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 3 from the ADIRU 1 (1FP1) to the first terminal block , ASM 341301.
A. If the test gives the maintenance message ADIRU1(1FP1)BUSX ADR/DMC3(1WT3)
Subtask 34-13-00-740-083-A - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 3 from the ADIRU 1 (1FP1) to the first terminal block , ASM 341301.
B. Do the test given in Para. 3.