Loss of the ADR 1 BUS 2 Output Identified by the SFCC 2
TASK 34-13-00-810-824-A
Loss of the ADR 1 BUS 2 Output Identified by the SFCC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-070-A 4. Fault Isolation
Subtask 34-13-00-810-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:22 UTC
Loss of the ADR 1 BUS 2 Output Identified by the SFCC 2
1. Possible Causes
- ADIRU-1 [1FP1]
wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-54-00-710-001 | Operational Test of the Flap System |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341301 |
Subtask 34-13-00-710-070-A 4. Fault Isolation
Subtask 34-13-00-810-073-A
A. If the test gives the maintenance message FLP2 : NO ADIRU1 DATA:
Subtask 34-13-00-710-071-A - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block , ASM 341301.
B. Do the test given in Para. 3.