Internal Failure of the ADR 1 Identified by the ECAM 2
TASK 34-13-00-810-803-A
Internal Failure of the ADR 1 Identified by the ECAM 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-710-050-A 4. Fault Isolation
Subtask 34-13-00-810-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:20 UTC
Internal Failure of the ADR 1 Identified by the ECAM 2
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-710-050-A 4. Fault Isolation
Subtask 34-13-00-810-052-A
A. If the test gives the maintenance message FWC2 : NO DATA FROM ADC1:
Subtask 34-13-00-710-051-A - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.