Internal Failure of the ADR 1 Identified by the EIS1
TASK 34-13-00-810-802-A
Internal Failure of the ADR 1 Identified by the EIS1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-051-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-051-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-051-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:20 UTC
Internal Failure of the ADR 1 Identified by the EIS1
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 34-13-00-740-051-A ** ON A/C NOT FOR ALL Subtask 34-13-00-740-051-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-13-00-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1 : NO ADC1 DATA:
Subtask 34-13-00-810-051-B ** ON A/C NOT FOR ALL - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
A. If the test gives the maintenance message ADIRU3(1FP3)BUSX ADR/DMC1(1WT1)
Subtask 34-13-00-740-052-A - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.