Internal Failure of the ADR 1
TASK 34-13-00-810-801-A
Internal Failure of the ADR 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-13-00-740-050-A 4. Fault Isolation
Subtask 34-13-00-810-050-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:20 UTC
Internal Failure of the ADR 1
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-12-34-610-801 | Uploading of Software to the ADIRUs |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-13-00-740-050-A 4. Fault Isolation
Subtask 34-13-00-810-050-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU1 (1FP1):
Subtask 34-13-00-810-050-C ** ON A/C NOT FOR ALL - replace the ADIRU-1 [1FP1] , AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
A. If the test gives the maintenance message ADIRU1 (1FP1):
- do the uploading of software to the ADIRU1 AMM 34-12-34-610-801.