Failure of the Angle of Attack Sensor 3
TASK 34-11-81-810-803-A
Failure of the Angle of Attack Sensor 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-81-700-052-A ** ON A/C NOT FOR ALL
Subtask 34-11-81-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:20 UTC
Failure of the Angle of Attack Sensor 3
1. Possible Causes
- SENSOR-ANGLE OF ATTACK, 3 [3FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
Subtask 34-11-81-700-052-A ** ON A/C NOT FOR ALL
A. Test
Not Applicable
4. Fault IsolationNot Applicable
Subtask 34-11-81-810-052-A ** ON A/C NOT FOR ALL
A. If the maintenance message AOA SENSOR (3FP3) is shown:
- replace the SENSOR-ANGLE OF ATTACK, 3 [3FP3] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.