Difference Between Pt3 and Ps3 Exceed the Treshold Value
TASK 34-11-00-810-911-A
Difference Between Pt3 and Ps3 Exceed the Treshold Value
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-153-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-11-00-810-254-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:19 UTC
Difference Between Pt3 and Ps3 Exceed the Treshold Value
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-10-00-170-003 | Draining and Flushing of Standby Pneumatic Circuits |
| AMM 34-11-15-000-001 | Removal of the Pitot Probe |
| AMM 34-11-15-200-001 | Inspection/Check of the Pitot Probe |
| AMM 34-11-15-400-001 | Installation of the Pitot Probe |
| AMM 34-11-16-200-001 | Inspection of the Static Port |
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-13-00-740-003 | SYSTEM TEST of the ADR |
Subtask 34-11-00-740-153-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-11-00-810-254-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADM3 (19FP3)/ ADM8 (19FP8):
Subtask 34-11-00-740-154-A ** ON A/C NOT FOR ALL - Do the inspection of the static port AMM 34-11-16-200-001.
- Do the draining and flushing of standby pneumatic circuits AMM 34-10-00-170-003.
- Do the inspection/check of the pitot probe 3 (9DA3) AMM 34-11-15-200-001.
- Replace the PROBE-PITOT, 3 [9DA3] AMM 34-11-15-000-001 and AMM 34-11-15-400-001.
- Replace the ADM-STBY TOTAL PRESSURE [19FP3] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- Replace the ADM-STBY STATIC PRESSURE [19FP8] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
B. Do the test given in Para. 3.