W DOC AIRBUS | TSM A320F

Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM


TASK 34-11-00-810-903-A
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM


1. Possible Causes
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-16-000-001
Removal of the Static Probe
AMM 34-11-16-400-002
Installation of the Static Probe
3. Fault Confirmation
Subtask 34-11-00-700-061-A ** ON A/C NOT FOR ALL
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
Subtask 34-11-00-810-233-A ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance message ADM6/7 (19FP6/7):
  • Do a visual check of the static probes.
   (1) If one static probe is damaged:
   (2) If the static probes are not damaged:
  • Do a check and repair the aircraft wiring between ADIRU2 pins AA/8D, 8E and ADM6 pins A/G, H.
  • Do a check and repair the aircraft wiring between ADIRU2 pins AA/9D, 9E and ADM7 pins A/G, H.
[Rev.8 from Aug 2018] 2026.04.04 04:32:19 UTC