Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
TASK 34-11-00-810-903-A
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-700-061-A ** ON A/C NOT FOR ALL
Subtask 34-11-00-810-233-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:19 UTC
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
1. Possible Causes
- aircraft wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-16-000-001 | Removal of the Static Probe |
| AMM 34-11-16-400-002 | Installation of the Static Probe |
Subtask 34-11-00-700-061-A ** ON A/C NOT FOR ALL
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-11-00-810-233-A ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance message ADM6/7 (19FP6/7):
- Do a visual check of the static probes.
- Replace the defective static probe AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
- Do a check and repair the aircraft wiring between ADIRU2 pins AA/8D, 8E and ADM6 pins A/G, H.
- Do a check and repair the aircraft wiring between ADIRU2 pins AA/9D, 9E and ADM7 pins A/G, H.