Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
TASK 34-11-00-810-900-A
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-142-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-11-00-810-228-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:19 UTC
Failure of the Pressure Transducer of the R Static Pressure ADM or of the L Static Pressure ADM
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-11-00-810-813-A | Failure of the Pressure Transducer of the L Static Pressure ADM |
| TSM TASK 34-11-00-810-814-A | Failure of the Pressure Transducer of the R Static Pressure ADM |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-11-00-740-142-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-11-00-810-228-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADM4 (19FP4):
Subtask 34-11-00-810-229-A ** ON A/C NOT FOR ALL - refer to (Ref. TSM TASK 34-11-00-810-814).
B. If the test gives the maintenance message ADM5 (19FP5):
- refer to (Ref. TSM TASK 34-11-00-810-813).