Deterioration of the Angle of Attack Sensor 1
TASK 34-11-00-810-892-A
Deterioration of the Angle of Attack Sensor 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-710-092-A
Subtask 34-11-00-810-208-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:18 UTC
Deterioration of the Angle of Attack Sensor 1
1. Possible Causes
- SENSOR-ANGLE OF ATTACK, 1 [3FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-19-000-001 | Removal of the Angle of Attack Sensor |
| AMM 34-11-19-400-001 | Installation of the Angle of Attack Sensor |
Subtask 34-11-00-710-092-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-11-00-810-208-B
A. If the PFR gives the class2 fault message AOA SENSOR1 (3FP1)/ADIRU1 (1FP1) and the logbook gives the maintenance status "ADR1":
Subtask 34-11-00-810-209-A ** ON A/C NOT FOR ALL - Do a visual check of the angle of attack sensor 1 (3FP1).
- Replace the SENSOR-ANGLE OF ATTACK, 1 [3FP1] AMM 34-11-19-000-001 and AMM 34-11-19-400-001.
- No other action is necessary.
- Replace the SENSOR-ANGLE OF ATTACK, 1 [3FP1] .
B. If the maintenance message AOA SNSR1 (3FP1)/ADIRU1 (1FP1) is shown on the Ground Scanning report, after the test of the angle-of- attack warning:
Subtask 34-11-00-810-209-D ** ON A/C NOT FOR ALL - no maintenance action is necessary.
NOTE: At the end of the test, on the ADIRS CDU, it is necessary to set the OFF/NAV/ATT selector switch related to the ADIRU1 to OFF for some seconds then to NAV to cancel the messages (fast re-alignment is not sufficient).
B. If the maintenance message AOA SNSR1 (3FP1)/ADIRU1 (1FP1) is shown on the Ground Scanning report, after the test of the angle-of-attack warning:
Subtask 34-11-00-810-209-E ** ON A/C NOT FOR ALL - no maintenance action is necessary.
NOTE: At the end of the test, on the ADIRS MSU, it is necessary to set the OFF/NAV/ATT selector switch related to the ADIRU1 to OFF for some seconds then to NAV to cancel the messages (fast re-alignment is not sufficient)
B. If the maintenance message AOA SENSOR1 (3FP1)/ADIRU1 (1FP1) is shown on the Ground Scanning report, after the test of the angle-of-attack warning:
- no maintenance action is necessary.
NOTE: At the end of the test, on the ADIRS MSU, it is necessary to set the OFF/NAV/ATT selector switch related to the ADIRU1 to OFF for some seconds then to NAV to cancel the messages (fast re-alignment is not sufficient)