W DOC AIRBUS | TSM A320F

Air Data Portion of the ADIRU3 Unserviceable


TASK 34-11-00-810-891-A
Air Data Portion of the ADIRU3 Unserviceable


1. Possible Causes
  • ADIRU-3 [1FP3]
  • ADM-STBY TOTAL PRESSURE [19FP3]
  • ADM-STBY STATIC PRESSURE [19FP8]
  • wiring between the ADIRU3 and the connector receptacle of the STBY total pressure ADM (19FP3)
  • wiring between the connector receptacle of the STBY static pressure ADM (19FP8) and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341303
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-11-00-740-138-A
A. Do the interface test of the IR (system 3) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-11-00-810-205-B
A. If the test gives the maintenance message ADIRU3 (1FP3) ADR BUS 1:
   (1) If the fault stops:
  • replace the ADIRU that you installed on side 1.
   (2) If the fault continues:
  • get access to the ADM-STBY TOTAL PRESSURE [19FP3] and ADM-STBY STATIC PRESSURE [19FP8] AMM 34-11-17-000-001 (Para. 2.A.)
  • disconnect the electrical connector of the STBY total pressure ADM (19FP3) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
     (a) If the voltages are not OK:
  • do a check and repair the wiring between the ADIRU3 and the connector receptacle of the STBY total pressure ADM (19FP3): for pins AA/6G, 6H and 6J of the ADIRU3 and pins A/A, C and E of the connector receptacle
  • connect the electrical connector of the STBY total pressure ADM (19FP3).
     (b) If the voltages are OK:
  • disconnect the electrical connector of the STBY static pressure ADM (19FP8) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
       1 If the voltages are not OK:
  • do a check and repair the wiring between the connector receptacle of the STBY static pressure ADM (19FP8) and the first terminal block: for pins A/A, C and E of the connector receptacle
  • connect the electrical connectors of the STBY total pressure ADM (19FP3) and the STBY static pressure ADM (19FP8).
       2 If the voltages are OK and if the fault continues:
         a If the fault continues :
  • replace the ADM-STBY STATIC PRESSURE [19FP8] .
Subtask 34-11-00-740-139-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:18 UTC