Air Data Portion of the ADIRU2 Unserviceable


TASK 34-11-00-810-890-A
Air Data Portion of the ADIRU2 Unserviceable


1. Possible Causes
  • ADIRU-2 [1FP2]
  • ADM-R TOTAL PRESSURE [19FP2]
  • ADM-R STATIC PRESSURE [19FP6]
  • ADM-L STATIC PRESSURE [19FP7]
  • wiring between the ADIRU2 and the connector receptacle of the R total pressure ADM (19FP2)
  • wiring between the connector receptacle of the R static pressure ADM (19FP6) and the first terminal block
  • wiring between the connector receptacle of the L static pressure ADM (19FP7) and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341303
AMM 34-14-00-740-001
Interface Test of the IR
3. Fault Confirmation
Subtask 34-11-00-740-136-A
A. Do the interface test of the IR (system 2) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-11-00-810-207-B
A. If the test gives the maintenance message ADIRU2 (1FP2) ADR BUS 1:
   (1) If the fault stops:
  • replace the ADIRU that you installed on side 1.
   (2) If the fault continues:
  • get access to the ADM-R TOTAL PRESSURE [19FP2] , ADM-R STATIC PRESSURE [19FP6] and ADM-L STATIC PRESSURE [19FP7] AMM 34-11-17-000-001 (Para. 2.A.)
  • disconnect the electrical connector of the L total pressure ADM (19FP2) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
     (a) If the voltages are not OK:
  • do a check and repair the wiring between the ADIRU2 and the connector receptacle of the R total pressure ADM (19FP2): for pins AA/6G, 6H and 6J of the ADIRU2 and pins A/A, C and E of the connector receptacle
  • connect the electrical connector of the R total pressure ADM (19FP2).
     (b) If the voltages are OK:
  • disconnect the electrical connector of the R static pressure ADM (19FP6) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
       1 If the voltages are not OK:
  • do a check and repair the wiring between the connector receptacle of the R static pressure ADM (19FP6) and the first terminal block: for pins A/A, C and E of the connector receptacle
  • connect the electrical connectors of the R total pressure ADM (19FP2) and the R static pressure ADM (19FP6).
       2 If the voltages are OK:
  • disconnect the electrical connector of the L static pressure ADM (19FP7) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
         a If the voltages are not OK:
  • do a check and repair the wiring between the connector receptacle of the L static pressure ADM (19FP7) and the first terminal block: for pins A/A, C and E of the connector receptacle
  • connect the electrical connectors of the L total pressure ADM (19FP2) and the R static pressure ADM (19FP6) and the L static pressure ADM (19FP7).
         b If the voltages are OK and if the fault continues:
* If the fault continues:
replace the ADM-L STATIC PRESSURE [19FP7] .
Subtask 34-11-00-740-137-A
B. Do the test given in Para. 3.