Air Data Portion of the ADIRU1 Unserviceable
TASK 34-11-00-810-889-A
Air Data Portion of the ADIRU1 Unserviceable
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-134-A 4. Fault Isolation
Subtask 34-11-00-810-206-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:18 UTC
Air Data Portion of the ADIRU1 Unserviceable
1. Possible Causes
- ADIRU-1 [1FP1]
- ADM-L TOTAL PRESSURE [19FP1]
- ADM-R STATIC PRESSURE [19FP4]
- ADM-L STATIC PRESSURE [19FP5]
wiring between the ADIRU1 and the connector receptacle of the L total pressure ADM (19FP1) wiring between the connector receptacle of the R static pressure ADM (19FP4) and the first terminal block wiring between the connector receptacle of the L static pressure ADM (19FP5) and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| ASM 341303 | |
| AMM 34-14-00-740-001 | Interface Test of the IR |
Subtask 34-11-00-740-134-A 4. Fault Isolation
Subtask 34-11-00-810-206-B
A. If the test gives the maintenance message ADIRU1 (1FP1) ADR BUS 1:
replace the ADM-L STATIC PRESSURE [19FP5] .
Subtask 34-11-00-740-135-A - swap the ADIRU-1 [1FP1] and the ADIRU2 AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the ADIRU that you installed on side 2.
- get access to the ADM-L TOTAL PRESSURE [19FP1] , ADM-R STATIC PRESSURE [19FP4] and ADM-L STATIC PRESSURE [19FP5] AMM 34-11-17-000-001 (Para. 2.A.)
- disconnect the electrical connector of the L total pressure ADM (19FP1) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
- do a check and repair the
wiring between the ADIRU1 and the connector receptacle of the L total pressure ADM (19FP1) : for pins AA/6G, 6H and 6J of the ADIRU1 and pins A/A, C and E of the connector receptacle - connect the electrical connector of the L total pressure ADM (19FP1).
- disconnect the electrical connector of the R static pressure ADM (19FP4) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
- do a check and repair the
wiring between the connector receptacle of the R static pressure ADM (19FP4) and the first terminal block : for pins A/A, C and E of the connector receptacle - connect the electrical connectors of the L total pressure ADM (19FP1) and the R static pressure ADM (19FP4).
- disconnect the electrical connector of the L static pressure ADM (19FP5) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle ASM 341303.
- do a check and repair the
wiring between the connector receptacle of the L static pressure ADM (19FP5) and the first terminal block : for pins A/A, C and E of the connector receptacle - connect the electrical connectors of the L total pressure ADM (19FP1) and the R static pressure ADM (19FP4) and the L static pressure ADM (19FP5).
- replace the ADM-L TOTAL PRESSURE [19FP1] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
. If the fault continues:
replace the ADM-R STATIC PRESSURE [19FP4] .
replace the ADM-L STATIC PRESSURE [19FP5] .
B. Do the test given in Para. 3.