Different Total Air Temperature on the ADIRUs
TASK 34-11-00-810-865-A
Different Total Air Temperature on the ADIRUs
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-710-080-A
Subtask 34-11-00-810-175-B ** ON A/C NOT FOR ALL
Subtask 34-11-00-860-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:57 UTC
Different Total Air Temperature on the ADIRUs
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-31-34-000-002 | Removal of the Probe Heat Computer (PHC) |
| AMM 30-31-34-400-002 | Installation of the Probe Heat Computer (PHC) |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| ASM 341102 | |
| AMM 34-11-18-000-001 | Removal of the TAT Sensor |
| AMM 34-11-18-400-001 | Installation of the TAT Sensor |
Subtask 34-11-00-710-080-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-11-00-810-175-B ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance message TAT SENSOR (11FP1)/ TAT SENSOR (11FP2):
1 If the value of the TAT sensor 1 or TAT sensor 3 is different from the external ambient temperature:
Subtask 34-11-00-810-175-H ** ON A/C NOT FOR ALL - make sure that the scoop and the choke of the TAT sensor 1 and TAT sensor 2 are not clogged or dirty.
- repair the defective TAT sensor.
- do the EIS start procedure (lower ECAM DU, F/O ND and CAPT ND only) AMM 31-60-00-860-001,
- do the ADIRS start procedure AMM 34-10-00-860-002,
- write the TAT2 value (given by the ADR2) shown at the bottom of the lower ECAM DU,
- on the SWITCHING panel 8VU, set the ECAM/ND XFR selector switch to CAPT,
- write the TAT1 value (given by the ADR1) shown at the L bottom of the CAPT ND,
- on the SWITCHING panel 8VU, set the AIR DATA selector switch to CAPT/3,
- write the TAT3 value (given by the ADR3) shown at the L bottom of the lower ECAM DU.
1 If the value of the TAT sensor 1 or TAT sensor 3 is different from the external ambient temperature:
- replace the SENSOR-TAT, 1 [11FP1] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.
- replace the SENSOR-TAT, 2 [11FP2] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.
- disconnect the electrical connectors from the TAT sensors 1 and 2
- do a check of the resistance between pins A/B and A/C of the TAT sensors 1 and 2.
ASM 341102
NOTE: The resistance value that follow are given for an ambient temperature of more than 0 deg. C.
a If the resistance value of the TAT sensor 1 is more than 31 ohms (open circuit) or less than 18 ohms (short circuit): - replace the TAT sensor 1.
- replace the TAT sensor 2.
- replace the PHC-1 [6DA1] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- replace the PHC-2 [6DA2] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
A. If the POST FLIGHT REPORT gives the maintenance message TAT SENSOR (11FP1)/TAT SENSOR (11FP2):
1 If the value of the TAT sensor 1 or TAT sensor 3 is different from the external ambient temperature:
5. Close-up- make sure that the scoop and the choke of the TAT sensor 1 and TAT sensor 2 are not clogged or dirty.
- repair the defective TAT sensor.
- do the EIS start procedure (lower ECAM DU, F/O ND and CAPT ND only) AMM 31-60-00-860-001,
- do the ADIRS start procedure AMM 34-10-00-860-002,
- write the TAT1 value (given by the ADR1) shown at the bottom of the lower ECAM DU,
- on the SWITCHING panel 8VU, set the ECAM/ND XFR selector switch to F/O,
- write the TAT2 value (given by the ADR2) shown at the L bottom of the F/O ND,
- on the SWITCHING panel 8VU, set the ECAM/ND XFR selector switch to NORM,
- on the SWITCHING panel 8VU, set the AIR DATA selector switch to CAPT/3,
- write the TAT3 value (given by the ADR3) shown at the L bottom of the lower ECAM DU.
1 If the value of the TAT sensor 1 or TAT sensor 3 is different from the external ambient temperature:
- replace the SENSOR-TAT, 1 [11FP1] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.
- replace the SENSOR-TAT, 2 [11FP2] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.
- disconnect the electrical connectors from the TAT sensors 1 and 2
- do a check of the resistance between pins A/B and A/C of the TAT sensors 1 and 2.
ASM 341102
NOTE: The resistance value that follow are given for an ambient temperature of more than 0 deg. C.
a If the resistance value of the TAT sensor 1 is more than 24 ohms (open circuit) or less than 18 ohms (short circuit): - replace the TAT sensor 1.
- replace the TAT sensor 2.
- replace the PHC-1 [6DA1] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
- replace the PHC-2 [6DA2] AMM 30-31-34-000-002 and AMM 30-31-34-400-002.
Subtask 34-11-00-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the SWITCHING panel 8VU, set the ECAM/ND XFR and AIR DATA selector switches to NORM.
(2) On the ADIR CDU, set the OFF/NAV/ATT selector switches to OFF.
(3) On the panel 301VU, set the ND potentiometer to OFF.
(4) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.
Subtask 34-11-00-860-050-C ** ON A/C NOT FOR ALL (1) On the SWITCHING panel 8VU, set the ECAM/ND XFR and AIR DATA selector switches to NORM.
(2) On the ADIR CDU, set the OFF/NAV/ATT selector switches to OFF.
(3) On the panel 301VU, set the ND potentiometer to OFF.
(4) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.
A. Put the aircraft back to its initial configuration.
(1) On the SWITCHING panel 8VU, set the ECAM/ND XFR and AIR DATA selector switches to NORM.
(2) On the ADIR MSU, set the OFF/NAV/ATT selector switches to OFF.
(3) On the CAPT LIGHTING/LOUD SPEAKER CTL panel 301VU, set the ND potentiometer to OFF.
(4) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.
(1) On the SWITCHING panel 8VU, set the ECAM/ND XFR and AIR DATA selector switches to NORM.
(2) On the ADIR MSU, set the OFF/NAV/ATT selector switches to OFF.
(3) On the CAPT LIGHTING/LOUD SPEAKER CTL panel 301VU, set the ND potentiometer to OFF.
(4) On the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.