Failure of the TAT Sensor 2
TASK 34-11-00-810-864-A
Failure of the TAT Sensor 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-710-079-A
Subtask 34-11-00-810-174-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:17 UTC
Failure of the TAT Sensor 2
1. Possible Causes
- SENSOR-TAT, 2 [11FP2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-18-000-001 | Removal of the TAT Sensor |
| AMM 34-11-18-400-001 | Installation of the TAT Sensor |
Subtask 34-11-00-710-079-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-11-00-810-174-B
A. If the maintenance message TAT SENSOR (11FP2) is shown:
- replace the SENSOR-TAT, 2 [11FP2] AMM 34-11-18-000-001 and AMM 34-11-18-400-001.