W DOC AIRBUS | TSM A320F

No AOA Test Activation


TASK 34-11-00-810-862-A
No AOA Test Activation


1. Possible Causes
  • ADIRU-1 [1FP1]
  • RELAY-AOA 1 TEST [21FP1]
  • wiring of the AOA 1 TEST relay (21FP1)
  • wiring of the ground signal at angle of attack sensor 1 (3FP1)
  • SENSOR-ANGLE OF ATTACK, 1 [3FP1]
  • ADIRU-2 [1FP2]
  • RELAY-AOA 2 TEST [21FP2]
  • wiring of the AOA 2 TEST relay (21FP2)
  • wiring of the ground signal at angle of attack sensor 2 (3FP2)
  • SENSOR-ANGLE OF ATTACK, 2 [3FP2]
  • ADIRU-3 [1FP3]
  • RELAY-AOA 3 TEST [21FP3]
  • wiring of the AOA 3 TEST relay (21FP3)
  • wiring of the ground signal at angle of attack sensor 3 (3FP3)
  • SENSOR-ANGLE OF ATTACK, 3 [3FP3]
  • wiring from the ADIRS/ADIRU/3SWTG/SPLY circuit breaker (9FP) to the first terminal block
  • C/B-ADIRS/ADIRU/3PWR/SWTG [9FP]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-10-00-710-007
Test of the Angle of Attack Warning
ASM 341101
ASM 341102
AMM 34-11-19-000-001
Removal of the Angle of Attack Sensor
AMM 34-11-19-400-001
Installation of the Angle of Attack Sensor
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 34-11-00-710-081-A
A. Test
   (1) Do the test of the angle of attack warning AMM 34-10-00-710-007.
4. Fault Isolation
Subtask 34-11-00-865-053-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
Subtask 34-11-00-810-177-A
B. If you cannot start the test of the angle of attack sensor 1 on the MCDU:
   (1) If the fault continues:
  • replace the RELAY-AOA 1 TEST [21FP1]
     (a) If the fault continues:
  • do a check of the wiring of the AOA 1 TEST relay (21FP1):
    . from pin A/A to the first terminal block
    . from pin A/X to the first terminal block
    . from pin A/Z to ADIRU1 (1FP1) pin AA/12G
    . from pin A/2 to angle of attack sensor 1 (3FP1) pin A/X
    ASM 341102.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • do a check of the wiring of the ground signal at angle of attack sensor 1 (3FP1) pin A/V ASM 341102.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
Subtask 34-11-00-810-178-A
C. If you cannot start the test of the angle of attack sensor 2 on the MCDU:
   (1) If the fault continues:
  • replace the RELAY-AOA 2 TEST [21FP2]
     (a) If the fault continues:
  • do a check of the wiring of the AOA 2 TEST relay (21FP2):
    . from pin A/A to the first terminal block
    . from pin A/X to the first terminal block
    . from pin A/Z to ADIRU2 (1FP2) pin AA/12G
    . from pin A/2 to angle of attack sensor 2 (3FP2) pin A/W
    ASM 341102.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • do a check of the wiring of the ground signal at angle of attack sensor 2 (3FP2) pin A/V ASM 341102.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
Subtask 34-11-00-810-179-A
D. If you cannot start the test of the angle of attack sensor 3 on the MCDU:
   (1) If the fault continues:
  • replace the RELAY-AOA 3 TEST [21FP3]
     (a) If the fault continues:
  • do a check of the wiring of the AOA 3 TEST relay (21FP3):
    . from pin A/A to the first terminal block
    . from pin A/X to the first terminal block
    . from pin A/Z to ADIRU3 (1FP3) pin AA/12G
    . from pin A/2 to angle of attack sensor 3 (3FP3) pin A/X
    ASM 341102.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • do a check of the wiring of the ground signal at angle of attack sensor 3 (3FP3) pin A/V ASM 341102.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
Subtask 34-11-00-810-180-A
E. If you cannot start the test of all the angle of attack sensors on the MCDU:
  • do a check of the wiring from the ADIRS/ADIRU/3SWTG/SPLY circuit breaker (9FP) to the first terminal block ASM 341101.
   (1) If there is non continuity:
  • repair the above wiring.
   (2) If there is continuity:
  • replace the C/B-ADIRS/ADIRU/3PWR/SWTG [9FP] .
Subtask 34-11-00-710-082-A
F. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:17 UTC