Different Average Static Pressure on the ADIRU 1 and the ADIRU 3
TASK 34-11-00-810-856-A
Different Average Static Pressure on the ADIRU 1 and the ADIRU 3
1. Possible Causes
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-710-072-A
Subtask 34-11-00-810-160-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:16 UTC
Different Average Static Pressure on the ADIRU 1 and the ADIRU 3
1. Possible Causes
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ARINC READER |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-10-00-170-002 | Flushing of the Principal Static Pressure Lines |
| AMM 34-10-00-170-003 | Draining and Flushing of Standby Pneumatic Circuits |
| AMM 34-10-00-860-002 | ADIRS Start Procedure |
| AMM 34-11-16-000-001 | Removal of the Static Probe |
| AMM 34-11-16-400-002 | Installation of the Static Probe |
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-13-00-790-002 | Leak Test of the Principal Static and Total Air Data System |
| ASM 341301 | |
| AMM 34-22-25-170-001 | Draining and Flushing of the Standby Static and Standby Total Pressure lines (ISIS) |
Subtask 34-11-00-710-072-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-11-00-810-160-B ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance message ADIRU1 (1FP1)/ ADIRU3 (1FP3):
Subtask 34-11-00-810-160-D ** ON A/C NOT FOR ALL - do a visual check of the static probes.
- replace the defective static probe AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
- do the ADIRS start procedure AMM 34-10-00-860-002
- connect the ARINC READER to the test connector 198VC on the panel 188VU and to the test connector 199VC or the panel 187VU ASM 341301
- compare the static ADM pressure read on these labels:
ADIRU 1 199VC ! 19FP5 LABEL 177 pins GG, HH ! 19FP4 LABEL 176 ! ADIRU 3 199VC ! 19FP8 LABEL 245 pins y, z !
- replace the defective static pressure ADM AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- do the flushing of the static pressure line of the air data module (ADM 4 and ADM 5) AMM 34-10-00-170-002
- do the draining and flushing of the standby static and standby total pressure line of the air data module AMM 34-10-00-170-003
- do the leak test of the main air data system (CAPT and F/O) AMM 34-13-00-790-002.
A. If the POST FLIGHT REPORT gives the maintenance message ADIRU1 (1FP1)/ ADIRU3 (1FP3):
Subtask 34-11-00-810-161-A - do a visual check of the static probes.
- replace the defective static probe AMM 34-11-16-000-001 and AMM 34-11-16-400-002.
- do the ADIRS start procedure AMM 34-10-00-860-002
- connect the ARINC READER to the test connector 198VC on the panel 188VU and to the test connector 199VC or the panel 187VU ASM 341301
- compare the static ADM pressure read on these labels:
ADIRU 1 199VC ! 19FP5 LABEL 177 pins GG, HH ! 19FP4 LABEL 176 ! ADIRU 3 199VC ! 19FP8 LABEL 245 pins y, z !
- replace the defective static pressure ADM AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- do the flushing of the static pressure line of the air data module (ADM 4 and ADM 5) AMM 34-10-00-170-002
- do the draining and flushing of the standby static and standby total pressure line of the air data module AMM 34-22-25-170-001
- do the leak test of the main air data system (CAPT and F/O) AMM 34-13-00-790-002.
B. After the subsequent flight, if the fault continues:
Subtask 34-11-00-810-162-A Subtask 34-11-00-810-163-A - replace the ADM-L STATIC PRESSURE [19FP5] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
D. After the subsequent flight, if the fault continues:
- replace the ADM-STBY STATIC PRESSURE [19FP8] .