W DOC AIRBUS | TSM A320F

Failure of the ADM Power Supply for the ADIRU 1


TASK 34-11-00-810-820-A
Failure of the ADM Power Supply for the ADIRU 1


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
3. Fault Confirmation
Subtask 34-11-00-740-088-A
A. Test
Do the Interface test of the ADR (system 1) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-11-00-740-089-A
A. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:15 UTC