Failure of the Pressure Transducer of the Standby Total Pressure ADM
TASK 34-11-00-810-818-A
Failure of the Pressure Transducer of the Standby Total Pressure ADM
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-084-A 4. Fault Isolation
Subtask 34-11-00-810-067-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:14 UTC
Failure of the Pressure Transducer of the Standby Total Pressure ADM
1. Possible Causes
- ADM-STBY TOTAL PRESSURE [19FP3]
- ADIRU-3 [1FP3]
wiring between standby total pressure ADM (19FP3) and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| ASM 341303 |
Subtask 34-11-00-740-084-A 4. Fault Isolation
Subtask 34-11-00-810-067-B
A. If the test gives the maintenance message ADM3 (19FP3):
Subtask 34-11-00-740-085-A - replace the ADM-STBY TOTAL PRESSURE [19FP3] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring between standby total pressure ADM (19FP3) and the first terminal block pins A/A, C, E ASM 341303.
B. Do the test given in Para. 3.