Failure of the Pressure Transducer of the Standby Total Pressure ADM


TASK 34-11-00-810-818-A
Failure of the Pressure Transducer of the Standby Total Pressure ADM


1. Possible Causes
  • ADM-STBY TOTAL PRESSURE [19FP3]
  • ADIRU-3 [1FP3]
  • wiring between standby total pressure ADM (19FP3) and the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-11-17-000-001
Removal of the Air Data Module
AMM 34-11-17-400-001
Installation of the Air Data Module
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-13-00-740-002
INTERFACE TEST of the ADR
ASM 341303
3. Fault Confirmation
Subtask 34-11-00-740-084-A
A. Test
Do the Interface test of the ADR (system 3) AMM 34-13-00-740-002.
4. Fault Isolation
Subtask 34-11-00-810-067-B
A. If the test gives the maintenance message ADM3 (19FP3):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between standby total pressure ADM (19FP3) and the first terminal block pins A/A, C, E ASM 341303.
Subtask 34-11-00-740-085-A
B. Do the test given in Para. 3.