Failure of the Pressure Transducer of the R Total Pressure ADM
TASK 34-11-00-810-815-A
Failure of the Pressure Transducer of the R Total Pressure ADM
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-078-A 4. Fault Isolation
Subtask 34-11-00-810-064-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:14 UTC
Failure of the Pressure Transducer of the R Total Pressure ADM
1. Possible Causes
- ADM-R TOTAL PRESSURE [19FP2]
- ADIRU-2 [1FP2]
wiring between R total pressure ADM (19FP2) and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| ASM 341303 |
Subtask 34-11-00-740-078-A 4. Fault Isolation
Subtask 34-11-00-810-064-B
A. If the test gives the maintenance message ADM2 (19FP2):
Subtask 34-11-00-740-079-A - replace the ADM-R TOTAL PRESSURE [19FP2] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring between R total pressure ADM (19FP2) and the first terminal block pins A/A, C, E ASM 341303.
B. Do the test given in Para. 3.