Loss of the ADM BUS 1 Input Data to the ADIRU 2
TASK 34-11-00-810-807-A
Loss of the ADM BUS 1 Input Data to the ADIRU 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-740-062-A 4. Fault Isolation
Subtask 34-11-00-810-056-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:14 UTC
Loss of the ADM BUS 1 Input Data to the ADIRU 2
1. Possible Causes
- ADM-R TOTAL PRESSURE [19FP2]
- ADIRU-2 [1FP2]
wiring of the ADM BUS 1 INPUT bus from the R total pressure ADM (19FP2) to the ADIRU 2 (1FP2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-11-17-000-001 | Removal of the Air Data Module |
| AMM 34-11-17-400-001 | Installation of the Air Data Module |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
| ASM 341303 |
Subtask 34-11-00-740-062-A 4. Fault Isolation
Subtask 34-11-00-810-056-B
A. If the test gives the maintenance message ADM2 (19FP2)/ADIRU2 (1FP2):
Subtask 34-11-00-740-063-A - replace the ADM-R TOTAL PRESSURE [19FP2] AMM 34-11-17-000-001 and AMM 34-11-17-400-001.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the
wiring of the ADM BUS 1 INPUT bus from the R total pressure ADM (19FP2) to the ADIRU 2 (1FP2) ASM 341303.
B. Do the test given in Para. 3.