Loss of the 26VAC Power Supply of the ADIRU 2
TASK 34-11-00-810-802-A
Loss of the 26VAC Power Supply of the ADIRU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-11-00-865-051-A
Subtask 34-11-00-810-051-B
[Rev.8 from Aug 2018]
2026.04.04 04:32:13 UTC
Loss of the 26VAC Power Supply of the ADIRU 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 341101 | |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 34-11-00-865-051-A
A. Table of the circuit breakers used in this procedure:
Subtask 34-11-00-740-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
B. Test
(1) Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
(a) If you cannot close the circuit breaker (5FP2), go to Para. 4.A.(2).
4. Fault Isolation(1) Do the Interface test of the ADR (system 2) AMM 34-13-00-740-002.
(a) If you cannot close the circuit breaker (5FP2), go to Para. 4.A.(2).
Subtask 34-11-00-810-051-B
A. If the test gives the maintenance message AOA SENSOR2 (3FP2) SPLY:
(1) If the circuit breaker (5FP2) is closed:
Subtask 34-11-00-740-053-A (1) If the circuit breaker (5FP2) is closed:
- do a check for 26VAC at pins AC/10, 6 of the ADIRU 2 (1FP2).
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check for a ground signal at pins AC/4, 9 of the ADIRU 2 (1FP2).
- repair the wiring between ADIRU 2 pins AC/4, 9 and the ground terminal ASM 341101.
- do a check of the wiring between ADIRU 2 pins AC/10, 6 and the circuit breaker (5FP2) ASM 341101.
- repair the above wiring.
- replace the C/B-ADIRS/ADIRU/2/26VAC AND AOA [5FP2] .
- close the circuit breaker.
- replace the ADIRU-2 [1FP2] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check for a short to ground at the wiring between ADIRU 2 pins AC/10, 6 and the circuit breaker (5FP2) ASM 341101.
- repair the above wiring.
- replace the C/B-ADIRS/ADIRU/2/26VAC AND AOA [5FP2] .
B. Do the test given in Para. 3.