Emergency Lighting - Emergency Lighting in the Cabin come on when the EMER EXIT LT Switch is in the ARM Position
TASK 33-51-00-810-881-A
Emergency Lighting - Emergency Lighting in the Cabin come on when the EMER EXIT LT Switch is in the ARM Position
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-710-207-A
Subtask 33-51-00-810-223-A
Subtask 33-51-00-860-136-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:13 UTC
Emergency Lighting - Emergency Lighting in the Cabin come on when the EMER EXIT LT Switch is in the ARM Position
1. Possible Causes
- wiring
- SW-SIGNS/EMER EXIT LT [4WL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-004 | Check of the Manual Operation from the two Control Panels and of all the Cabin the Cabin Lights and Signs illuminated by Batteries |
| ASM 335101 |
Subtask 33-51-00-710-207-A
A. Do the operational test of manual operation of both control panels and check all cabin lights and signs illuminated by batteries AMM 33-51-00-710-004.
4. Fault IsolationSubtask 33-51-00-810-223-A
A. If the emergency lighting in the cabin comes on before the circuit breakers 1WL and 2WL are opened:
Subtask 33-51-00-710-208-A - do a check and repair the wiring between:
SW-SIGNS/EMER EXIT LT [4WL] switch pin 3C and POWER SUPPLY UNIT-EMERGENCY (10WL) connector A/<D,
SW-SIGNS/EMER EXIT LT [4WL] switch pin 2B and POWER SUPPLY UNIT-EMERGENCY (10WL) connector A/B,
SW-SIGNS/EMER EXIT LT [4WL] switch pin 3B and POWER SUPPLY UNIT-EMERGENCY (10WL) connector A/A
ASM 335101.
- do a check of the SW-SIGNS/EMER EXIT LT [4WL] and replace it if necessary.
B. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-136-A
A. Put the aircraft back to its initial configuration.