Failure of EPSU 13WL to communicate with the CIDS
TASK 33-51-00-810-860-A
Failure of EPSU 13WL to communicate with the CIDS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-176-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-115-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:12 UTC
Failure of EPSU 13WL to communicate with the CIDS
1. Possible Causes
- EPSU [13WL]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| ASM 335101 | |
| ASM 335102 | |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-164-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-176-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-177-A ** ON A/C NOT FOR ALL B. If the operational test gives the maintenance message:
(1) EPSU(13WL)AFT L/DEU B(300RH7):
Subtask 33-51-00-710-165-A ** ON A/C NOT FOR ALL (1) EPSU(13WL)AFT L/DEU B(300RH7):
- replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check and repair the wiring between:
EPSU 13WL pin -I and DEU-B 300RH7 pin B29.
EPSU 13WL pin -P and DEU-B 300RH7 pin B31.
EPSU 13WL pin X and DEU-B 300RH7 pin B30 ASM 335102.
- do a check of the electrical connections of the escape slide ASM 335101.
C. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-115-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.