W DOC AIRBUS | TSM A320F

Failure of the Emergency Lights controlled by EPSU 13WL


TASK 33-51-00-810-854-A
Failure of the Emergency Lights controlled by EPSU 13WL


1. Possible Causes
  • LIGHT-EMERGENCY, CABIN [32WL]
  • LIGHT-EMERGENCY, CABIN [33WL]
  • LIGHT EMERGENCY [205WL]
  • LIGHT EMERGENCY [207WL]
  • wiring
  • LIGHT EMERGENCY [208WL]
  • LIGHT EMERGENCY [210WL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-001
Operational Test of the Emergency Lights
AMM 33-51-00-710-007
Operational Test of the Emergency Lighting in the Cabin with the 'LIGHT EMER' Pushbutton Switch
ASM 335102
AMM 33-51-11-000-001
Removal of the Cabin Emergency Lights
AMM 33-51-11-400-001
Installation of the Cabin Emergency Light
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-152-A ** ON A/C NOT FOR ALL
A. Do the operational test of the emergency lights with the MCDU AMM 33-51-00-710-001.
4. Fault Isolation
Subtask 33-51-00-810-164-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-165-E ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) EMER LT/EPSU(13WL)AFT L:
     (a) If the fault continues:
  • Do a check and repair the wiring between:
    EPSU 13WL pin E and the LIGHT-EMERGENCY, CABIN [33WL] pin 3.
    LIGHT-EMERGENCY, CABIN [33WL] pin 1 and GND.
    EPSU 13WL pin E and the LIGHT EMERGENCY [205WL] pin 3.
    LIGHT EMERGENCY [205WL] pin 1 and GND.
    EPSU 13WL pin G and the LIGHT-EMERGENCY, CABIN [32WL] pin 3.
    LIGHT-EMERGENCY, CABIN [32WL] pin 1 and GND.
    EPSU 13WL pin G and the LIGHT EMERGENCY [207WL] pin 3.
    LIGHT EMERGENCY [207WL] pin 1 and GND ASM 335102.
Subtask 33-51-00-810-165-F ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) EMER LT/EPSU(13WL)AFT L:
     (a) If the fault continues:
  • Do a check and repair the wiring between:
    EPSU 13WL pin E and the LIGHT-EMERGENCY, CABIN [33WL] pin 3.
    LIGHT-EMERGENCY, CABIN [33WL] pin 1 and GND.
    EPSU 13WL pin E and the LIGHT EMERGENCY [208WL] pin 3.
    LIGHT EMERGENCY [208WL] pin 1 and GND.
    EPSU 13WL pin G and the LIGHT-EMERGENCY, CABIN [32WL] pin 3.
    LIGHT-EMERGENCY, CABIN [32WL] pin 1 and GND.
    EPSU 13WL pin G and the LIGHT EMERGENCY [210WL] pin 3.
    LIGHT EMERGENCY [210WL] pin 1 and GND ASM 335102.
Subtask 33-51-00-710-153-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 33-51-00-860-109-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:32:11 UTC