W DOC AIRBUS | TSM A320F

Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 13WL


TASK 33-51-00-810-845-A
Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 13WL


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-001
Operational Test of the Emergency Lights
AMM 33-51-00-710-007
Operational Test of the Emergency Lighting in the Cabin with the 'LIGHT EMER' Pushbutton Switch
ASM 335104
AMM 33-51-13-000-001
Removal of the Cabin Wall-Mounted Emergency-Exit-Markers
AMM 33-51-13-400-001
Installation of the Cabin Wall-Mounted Emergency-Exit-Markers
AMM 33-51-18-000-001
Removal of the Seat/Wall-Mounted Emergency-Exit Location-Light
AMM 33-51-18-400-001
Installation of the Seat/Wall-Mounted Emergency-Exit Location-Light
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-135-A ** ON A/C NOT FOR ALL
A. Do the operational test of the emergency lights with the MCDU AMM 33-51-00-710-001.
4. Fault Isolation
Subtask 33-51-00-810-144-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-145-B ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) FPEEPMS CROSSAISLE LT/EPSU(13WL)AFT L:
     (a) If the fault continues and:
       1 The EXIT MARKER [90WL5] is not illuminated:
  • do a check and repair the wiring between:
    lamp module 90WL5 pin 3 and EPSU 13WL pin -H.
    lamp module 90WL5 pin 1 and GND ASM 335104.
       2 The EXIT MARKER [90WL6] is not illuminated:
  • do a check and repair the wiring between:
    lamp module 91WL6 pin 3 and EPSU 13WL pin -H.
    lamp module 91WL6 pin 1 and GND ASM 335104.
       3 The [361WL3] is not illuminated:
  • do a check and repair the wiring between:
    lamp module 361WL3 pin 3 and EPSU 13WL pin -H.
    lamp module 361WL3 pin 1 and GND ASM 335104.
Subtask 33-51-00-810-145-E ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) FPEEPMS CROSSAISLE LT/EPSU(13WL)AFT L:
     (a) If the fault continues and:
       1 The EXIT MARKER [90WL7] is not illuminated:
  • do a check and repair the wiring between:
    lamp module 90WL7 pin 3 and EPSU 13WL pin -H.
    lamp module 90WL7 pin 1 and GND ASM 335104.
       2 The EXIT MARKER [90WL8] is not illuminated:
  • do a check and repair the wiring between:
    the lamp module 90WL8 pin 3 and EPSU 13WL pin -H.
    the lamp module 90WL8 pin 1 and GND ASM 335104.
Subtask 33-51-00-710-136-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 33-51-00-860-101-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.