Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 12WL
TASK 33-51-00-810-844-A
Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 12WL
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-142-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-100-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:10 UTC
Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 12WL
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| AMM 33-51-00-710-007 | Operational Test of the Emergency Lighting in the Cabin with the 'LIGHT EMER' Pushbutton Switch |
| ASM 335104 | |
| AMM 33-51-13-000-001 | Removal of the Cabin Wall-Mounted Emergency-Exit-Markers |
| AMM 33-51-13-400-001 | Installation of the Cabin Wall-Mounted Emergency-Exit-Markers |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-133-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-142-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-143-B ** ON A/C NOT FOR ALL B. If the operational test gives the maintenance message:
(1) FPEEPMS CROSSAISLE LT/EPSU(12WL)EMER R:
Subtask 33-51-00-810-143-E ** ON A/C NOT FOR ALL (1) FPEEPMS CROSSAISLE LT/EPSU(12WL)EMER R:
- replace the EXIT MARKER [90WL4] AMM 33-51-13-000-001 and AMM 33-51-13-400-001 if not illuminated.
- do a check and repair the wiring between:
lamp module 90WL4 pin 3 and EPSU 12WL pin -H.
lamp module 90WL4 pin 1 and GND ASM 335104.
B. If the operational test gives the maintenance message:
(1) FPEEPMS CROSSAISLE LT/EPSU(12WL)EMER R:
1 The EXIT MARKER [90WL4] is not illuminated:
Subtask 33-51-00-710-134-A ** ON A/C NOT FOR ALL (1) FPEEPMS CROSSAISLE LT/EPSU(12WL)EMER R:
- do the operational test of the emergency lighting in the cabin by pushbutton switch AMM 33-51-00-710-007.
- during the test monitor the EXIT MARKER [90WL4] and the EXIT MARKER [90WL6] ASM 335104.
- replace the EXIT MARKER [90WL4] AMM 33-51-13-000-001 and AMM 33-51-13-400-001 if not illuminated.
- replace the EXIT MARKER [90WL6] AMM 33-51-13-000-001 and AMM 33-51-13-400-001 if not illuminated ASM 335104.
1 The EXIT MARKER [90WL4] is not illuminated:
- do a check and repair the wiring between:
lamp module 90WL4 pin 3 and EPSU 12WL pin -H.
lamp module 90WL4 pin 1 and GND ASM 335104.
- do a check and repair the wiring between:
lamp module 90WL6 pin 3 and EPSU 12WL pin -H.
lamp module 90WL6 pin 1 and GND ASM 335104.
C. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-100-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.