Failure of the Battery of EPSU 10WL
TASK 33-51-00-810-829-A
Failure of the Battery of EPSU 10WL
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-111-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-085-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:09 UTC
Failure of the Battery of EPSU 10WL
1. Possible Causes
- battery of EPSU 10WL
- POWER-EMERGENCY SUPPLY [10WL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| AMM 33-51-00-710-003 | Check of the Battery Capacity |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-000-002 | Removal of the Battery of the Emergency Power-Supply Unit |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-002 | Installation of the Battery of the Emergency Power-Supply Unit |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-103-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-111-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-112-A ** ON A/C NOT FOR ALL B. If the operational test gives the maintenance message:
(1) BAT/EPSU(10WL)FWD L:
Subtask 33-51-00-810-115-A ** ON A/C NOT FOR ALL (1) BAT/EPSU(10WL)FWD L:
- Do the operational test of the emergency lights with the MCDU AMM 33-51-00-710-001.
C. If the test gives the maintenance message:
(1) BAT/EPSU(10WL)FWD L:
Subtask 33-51-00-710-104-A ** ON A/C NOT FOR ALL (1) BAT/EPSU(10WL)FWD L:
- replace the battery of EPSU 10WL AMM 33-51-38-000-002 and AMM 33-51-38-400-002.
- replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
D. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-085-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.