EPSU 10WL does not have a Test Result available


TASK 33-51-00-810-827-A
EPSU 10WL does not have a Test Result available


1. Possible Causes
  • wiring
  • POWER-EMERGENCY SUPPLY [10WL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-003
Check of the Battery Capacity
ASM 335101
AMM 33-51-38-000-001
Removal of the Emergency Power-Supply Unit (EPSU)
AMM 33-51-38-400-001
Installation of the Emergency Power-Supply Unit (EPSU)
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-099-A ** ON A/C NOT FOR ALL
A. Do the operational test 'Check Battery Capacity' with the MCDU AMM 33-51-00-710-003.
4. Fault Isolation
Subtask 33-51-00-810-107-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-108-A ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) NO TEST RESULT AVAIL/EPSU(10WL)FWD L:
     (a) Do a check and repair the wiring between:
EPSU 10WL pin -I and DEU-B 300RH1 pin B29.
EPSU 10WL pin -P and DEU-B 300RH1 pin B31.
EPSU 10WL pin X and DEU-B 300RH1 pin B30 ASM 335101.
     (b) If the fault continues:
Subtask 33-51-00-710-100-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 33-51-00-860-083-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.