Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 10WL
TASK 33-51-00-810-825-A
Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 10WL
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-103-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-081-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:09 UTC
Failure of the Crossaisle Lights (Floor Proximity Emergency Escape Path Marking System) controlled by EPSU 10WL
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| AMM 33-51-00-710-007 | Operational Test of the Emergency Lighting in the Cabin with the 'LIGHT EMER' Pushbutton Switch |
| ASM 335104 | |
| AMM 33-51-13-000-001 | Removal of the Cabin Wall-Mounted Emergency-Exit-Markers |
| AMM 33-51-13-400-001 | Installation of the Cabin Wall-Mounted Emergency-Exit-Markers |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-095-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-103-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-104-B ** ON A/C NOT FOR ALL B. If the operational test gives the maintenance message:
(1) FPEEPMS CROSSAISLE LT/EPSU(10WL)FWD L:
1 The EXIT MARKER [90WL1] is not illuminated:
Subtask 33-51-00-710-096-A ** ON A/C NOT FOR ALL (1) FPEEPMS CROSSAISLE LT/EPSU(10WL)FWD L:
- do the Operational Test of the Emergency Lighting in the Cabin by Pushbutton Switch AMM 33-51-00-710-007.
- during the test monitor the EXIT MARKER [90WL1] and the EXIT MARKER [90WL2] ASM 335104.
- replace the EXIT MARKER [90WL1] AMM 33-51-13-000-001 and AMM 33-51-13-400-001 if not illuminated.
- replace the EXIT MARKER [90WL2] AMM 33-51-13-000-001 and AMM 33-51-13-400-001 if not illuminated ASM 335104.
1 The EXIT MARKER [90WL1] is not illuminated:
- do a check and repair the wiring between:
lamp module 90WL1 pin 3 and EPSU 10WL pin -H.
lamp module 90WL1 pin 1 and GND ASM 335104.
- do a check and repair the wiring between:
lamp module 90WL2 pin 3 and EPSU 10WL pin -H.
lamp module 90WL2 pin 1 and GND ASM 335104.
C. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-081-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.