Emer. Lighting - The Exit Signs Flicker
TASK 33-51-00-810-819-A
Emer. Lighting - The Exit Signs Flicker
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-710-209-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-810-224-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-075-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:09 UTC
Emer. Lighting - The Exit Signs Flicker
1. Possible Causes
- RELAY 8WL
DIODE (on diode holder 1158VD) DIODE (in diode holder 1158VD)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 335100 | |
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
Subtask 33-51-00-710-209-A ** ON A/C NOT FOR ALL
A. Do this Test
(1) Do the operational test of the emergency lights by TEST EMER LIGHT SYS pushbutton AMM 33-51-00-710-001.
(2) On the overhead panel 25VU, set the NO SMOKING switch 190RH to the ON position.
(3) Monitor the EXIT signs in the cabin.
(4) On the overhead panel 25VU, set the NO SMOKING switch 190RH to the AUTO position.
(5) Monitor the EXIT signs in the cabin.
Subtask 33-51-00-710-209-C ** ON A/C NOT FOR ALL (1) Do the operational test of the emergency lights by TEST EMER LIGHT SYS pushbutton AMM 33-51-00-710-001.
(2) On the overhead panel 25VU, set the NO SMOKING switch 190RH to the ON position.
(3) Monitor the EXIT signs in the cabin.
(4) On the overhead panel 25VU, set the NO SMOKING switch 190RH to the AUTO position.
(5) Monitor the EXIT signs in the cabin.
A. Operational Test
(1) Do this test:
(a) Do the operational test of the emergency lights, refer to TEST EMER LIGHT SYS pushbutton AMM 33-51-00-710-001.
(b) On overhead panel 25VU, set No PED switch 190RH to the ON position.
(c) Monitor the EXIT signs in the cabin.
(d) On overhead panel 25VU, set No PED switch 190RH to the AUTO position.
(e) Monitor the EXIT signs in the cabin.
4. Fault Isolation(1) Do this test:
(a) Do the operational test of the emergency lights, refer to TEST EMER LIGHT SYS pushbutton AMM 33-51-00-710-001.
(b) On overhead panel 25VU, set No PED switch 190RH to the ON position.
(c) Monitor the EXIT signs in the cabin.
(d) On overhead panel 25VU, set No PED switch 190RH to the AUTO position.
(e) Monitor the EXIT signs in the cabin.
Subtask 33-51-00-810-224-A ** ON A/C NOT FOR ALL
A. If the exit signs in the cabin flicker with NO SMOKING switch 190RH in either the ON or the AUTO position:
Subtask 33-51-00-810-224-C ** ON A/C NOT FOR ALL - Replace RELAY 8WL in relay box 103VU in the electronics compartment ASM 335100.
- Replace the
DIODE (on diode holder 1158VD) between pins 31 and 32 on panel 103VU126 ASM 335100.
A. If the exit signs in the cabin flicker with No PED switch 190RH in one of the two the ON or the AUTO position:
Subtask 33-51-00-710-084-A - Replace RELAY 8WL in relay box 103VU in the electronics compartment, refer to ASM 335100.
- Replace the
DIODE (in diode holder 1158VD) between pins 31 and 32 on panel 103VU126 ASM 335100.
B. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-075-A
A. Put the aircraft back to its initial configuration.